Each example uses a real-world submittal shape with identifying details removed. Use them to calibrate expectations before enabling automated review in production.

Example: residential deck, 320 sq ft

Review path
Intake→
Sheet index→
Discipline routing→
Code checks→
Findings→
Correction letter
CheckResultReference
Guardrail height ≥ 42 inPassCRC R312.1.2
Guard opening < 4 in sphereFail — 5 in spacing shownCRC R312.1.3
Footing depth ≥ 12 in below gradeAdvisory — detail not dimensionedCRC R403.1.4
Ledger attachment detailPassCRC R507.9
image placeholder

Sheet A-101 with findings overlay